List of common error codes on spa control panels
Here is a list of the main error codes that appear on spa control panels. Just choose the control panel model and find the error code and the associated message.
Code |
Message |
OH / HL (Solid) |
Overheat – sensor has detected 118°F at heater |
OH /HL (Flashing) |
Over heat – sensor has detected 110°F spa water |
FLO / FL (Flashing) |
Pressure switch open, pump on |
FLO / FL (Solid) |
Pressure switch closed, pump off |
Cool |
Water temp 20°F below set point |
ICE / IC |
Potential freeze condition has been detected |
Sn1 / Sn |
Hi-limit sensor fault |
Sn3 / Sn |
Temp sensor fault |
ILOC |
Interlock fault |
Pd |
No power to spa pak, on battery backup |
SbY / StbY |
Spa is in standby mode |
Code |
Message |
OHH / HH / HTR TEMP LMT |
Overheat – spa has shut down, sensor has detected 118°F at heater |
OHs / OH / SPA TEMP LMT |
Overheat – spa has shut down, sensor has detected water temp 110°F |
ICE / IC |
Potential freeze condition has been detected |
SnA / SA / SENSOR / A SERVICE RQD |
Sensor plugged into ‘A’ port not working |
SnB / SB / SENSOR / B SERVICE RQD |
Sensor plugged into ‘B’ port not working |
SnS / Sn / SENSOR SYNC |
Sensors out of balance |
HFL / HL / HEATER FLOW LOW |
Substantial temperature difference between sensors, possible low flow condition |
LF / LOW FLOW |
Displays on the fifth occurrence of ‘HFL’ message within 24 hour period |
Dr / HEATER MAY BE DRY WILL RESET SHORTLY |
Inadequate water detected in heater, possible dry condition |
Dry / dy / HEATER DRY SERVICE RQD |
Inadequate water detected in heater, displays on third occurrence of ‘dr’ message |
Pr |
Priming mode – occurs when spa is powered up |
—/–/–F/–C |
Unkown water temperature / temperature not current |
PSt / PERSIST FAIL |
System PCB persistent memory could not be read / hardware fault |
SbY / STANDBY MODE |
Spa is in standby mode, all automatic functions are stopped |
CFE |
System configuration / conflict error |
SF/ SAFETY FAULT |
Suction protection circuit fault |
Code |
Message |
FLO / FL-O / rH-nF |
No water flow detected |
FL-C |
Pressure switch closed while pump off |
Prr / Pr-r / rH-Pr |
Temp sensor fault |
AOH / AO-H / SP-Ot |
Spa pack internal temp too high |
Fr- Er |
Input frequency (50/60Hz) is out of range |
SP-In |
Input voltage too low |
SP-Fx / Fx |
F1, F2 or F3 fuse is blown |
SP-OH / OH |
Overheat sensor has detected 108°F spa water |
SP-Hr / Hr |
Internal hardware error |
SP-br |
Breaker setting too low incorrect / input current setting |
rH-Hr |
Heater hardware error in.therm |
rH-nH |
Heater on, no water temp increase |
rH-nC |
Communication error between heater and spa pack |
rH-HL / HL |
Overheat – sensor has detected 119°F at heater |
rH-Id |
Incompatibility between spa pack and heater |
Sc |
Scanning outputs for current draw |
Sc-Er |
Scan error detected / system learning error |
P1-Er |
System detects no current change with pump-1 on |
P2-Er |
System detects no current change with pump-2 on |
P3/P4/P5-Er |
System detects no current change with pump 3, 4 or 5 on |
CP-Er |
System detects no current change with circ-pump on |
BL-Er |
System detects no current change with blower on |
Fn-Er |
System detects no current change with fan on |
Fb-Er |
Fiber optic failure |
Lxx/LLxx |
Low level software setting |
UPL/UP-Ld |
No low level software loaded |
StbY |
Standby mode |
OFF |
All outputs off for 30 minutes |
rLY |
Stuck relay |